VIDAR

Fully Packaged Three-Wave Mixing Travelling-Wave Parametric Amplifier

VIDAR - Fully Packaged Three-Wave Mixing TWPA

Near-Quantum-Limited Noise Performance in a 4 GHz BandDue to the 3-wave mixing and our patented dispersion engineering, our TWPA has 4 GHz of uninterrupted gain with near-quantum-limited noise performance.

Pump Outside of Gain BandThe pump frequency is well outside the gain band, reducing the risk of interference with the measured devices, and can easily be filtered out.

The QET Vidar TWPA is a package with a three-wave mixing TWPA, an integrated flux coil, ESD protection and magnetic flux protection, all in one package. It provides an easy-to-use solution with a large Signal-to-Noise Ratio improvement over a wide band, while minimizing the added thermal load to your cryostat.

Simple Flux BiasProvides both flux biasing via the internal coil, and protection from external flux.

Built-in ProtectionThe solution has inbuilt flux protection and ESD protection, ensuring an easy-to-use solution

Specifications

Expected Performance

Typical ∆SNR: 10-12 dB
Typical Gain: 15 dB
Bandwidth: 4-8 GHz
Expected Added Noise: <1 photon
Optimal Pump Frequency: ~12 GHz
Typical Pump Power: -80 dBm
Typical Saturation Power: -100 dBm

Port Configuration

Model S
Two RF-ports used for the TWPA. Two DC ports are used as input and output for the flux bias current

Model D
Two RF-ports used per TWPA. Two DC ports are used as input and output for the flux bias current

Specifications

Expected Performance

Typical Gain: 15 dB
Bandwidth: 4-8 GHz
Typical ∆SNR: 10-12 dB
Expected Added Noise: <1 photon
Optimal Pump Frequency: ~12 GHz
Typical Pump Power: -80 dBm
Typical Saturation Power: -100 dBm

Port Configuration

Model S
Two RF-ports used for the TWPA. Two DC ports are used as input and output for the flux bias current

Model D
Two RF-ports used per TWPA. Two DC ports are used as input and output for the flux bias current

VIDAR Models

Model S
Model S is a single-amplifier solution offering large bandwidth and very low noise.

Model D
Model D integrates two Three-Wave Mixing TWPAs into a single enclosure.

Product Sheets

Contact Sales

Submit your email to get in touch with the sales team about VIDAR

CliQ 10

Construction

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Donec luctus, nunc in iaculis vestibulum, nunc ex convallis est, ut viverra velit sapien ac erat. Vivamus aliquet mi tellus, vel viverra ex blandit sed. Sed blandit lobortis risus. Aliquam blandit cursus ex sed iaculis.

construction.jpeg

Medicine

In vel nulla ac enim pellentesque tristique vel non dui. Integer vulputate ex leo, in accumsan purus consectetur quis. Cras scelerisque orci vel dapibus volutpat. In et consectetur enim. Maecenas lobortis viverra tortor, quis fermentum sem volutpat sit amet.

medicine.jpeg

Real Estate

Donec consequat nibh at urna tincidunt tempor. Integer quis lobortis felis. Nulla id quam vestibulum, aliquam mauris vitae, auctor ex. Aliquam augue nulla, faucibus sed lacus ac, placerat elementum nisi. Curabitur enim nunc, dictum et accumsan.

real-estate.jpeg

Wellness

Morbi ullamcorper tellus eu purus dictum convallis. Duis posuere dui sit amet pellentesque malesuada. Morbi ultrices tortor ut diam molestie, vel pharetra lectus lacinia. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Aenean varius lectus lectus.

wellness.jpeg